#!/bin/sh
# Begin $rc_base/init.d/collecd
. /etc/sysconfig/rc
. $rc_functions
eval $(/usr/local/bin/readhash /var/ipfire/main/settings)
if [ "$RRDLOG" = '' ]; then
RRDLOG=/var/log/rrd
fi
case "$1" in
start)
if use_ramdisk; then
boot_mesg "Mounting RRD ramdisk..."
mount_ramdisk "${RRDLOG}"
evaluate_retval
fi
# If run from init and collectd alrady started then exit silent
if [ "$(basename $0)" != "collectd" ]; then
if [ "$(ps -A | grep " collectd$")" != "" ]; then
exit 0
fi
fi
# ARM does not support to scan for sensors. In that case,
# we create an empty configuration file.
machine=$(uname -m)
if [ "${machine:0:3}" = "arm" ]; then
touch /etc/sysconfig/lm_sensors
fi
if [ "${machine:0:7}" = "aarch64" ]; then
touch /etc/sysconfig/lm_sensors
fi
# Do not search for sensors when running on AWS
if [ -e "/var/run/aws-instance-id" ]; then
touch /etc/sysconfig/lm_sensors
fi
# At first run search for sensors with sensors-detect
if [ ! -e /etc/sysconfig/lm_sensors ]; then
boot_mesg "Searching for Sensors..."
# pre scan and try to load modules
"yes" | /usr/sbin/sensors-detect > /dev/null
if [ -e /etc/sysconfig/lm_sensors ]; then
# Module load
. /etc/sysconfig/lm_sensors
for modul in $BUS_MODULES $HWMON_MODULES ; do
modprobe $modul > /dev/null 2>&1;
done
fi
# Final scan
"yes" | /usr/sbin/sensors-detect > /dev/null
evaluate_retval
if [ ! -e /etc/sysconfig/lm_sensors ]; then
echo "#No Sensors detected " > /etc/sysconfig/lm_sensors
fi
fi
# Load sensor modules only first start
if [ ! -e /var/lock/sensors_modules ]; then
touch /var/lock/sensors_modules
boot_mesg -n "Loading Sensor Modules: "
. /etc/sysconfig/lm_sensors
for modul in $BUS_MODULES $HWMON_MODULES ; do
modprobe $modul > /dev/null 2>&1;
if [ ${?} = 0 ]; then
boot_mesg -n "$SUCCESS$modul$NORMAL ";
else
boot_mesg -n "$WARNING$modul$NORMAL ";
fi
done
boot_mesg;
echo_ok;
fi
# Enable sensors plugin if sensors found
if [ "$( sensors 2>&1 | grep 'No sensors found!' | wc -l )" == "1" ]; then
sed -i -e "s|^LoadPlugin sensors|#LoadPlugin sensors|g" /etc/collectd.conf
else
sed -i -e "s|^#LoadPlugin sensors|LoadPlugin sensors|g" /etc/collectd.conf
fi
# Enable thermal plugin if thermal_zone found
if [ ! -e /sys/class/thermal/thermal_zone0 ]; then
sed -i -e 's|^include "/etc/collectd.thermal"$|#include "/etc/collectd.thermal"|g' /etc/collectd.conf
else
sed -i -e 's|^#include "/etc/collectd.thermal"$|include "/etc/collectd.thermal"|g' /etc/collectd.conf
fi
# Enable cpufreq plugin if cpufreq found
if [ ! -e /sys/devices/system/cpu/cpu0/cpufreq/scaling_cur_freq ]; then
sed -i -e "s|^LoadPlugin cpufreq|#LoadPlugin cpufreq|g" /etc/collectd.conf
else
sed -i -e "s|^#LoadPlugin cpufreq|LoadPlugin cpufreq|g" /etc/collectd.conf
fi
# Enable swap plugin if swap found
if [ "$(swapon -s | wc -l)" == "0" ]; then
sed -i -e "s|^LoadPlugin swap|#LoadPlugin swap|g" /etc/collectd.conf
else
sed -i -e "s|^#LoadPlugin swap|LoadPlugin swap|g" /etc/collectd.conf
fi
# sync after config update...
sync
if [ $(date +%Y) -gt 2011 ]; then
boot_mesg "Starting Collection daemon..."
/usr/sbin/collectd -C /etc/collectd.conf
evaluate_retval
else
boot_mesg "collectd: cannot start with incorrect time ($(date))."
echo_warning;
fi
;;
stop)
boot_mesg "Stopping Collection daemon..."
killproc /usr/sbin/collectd
evaluate_retval
# Umount the ramdisk (if any)
umount_ramdisk "${RRDLOG}"
;;
restart)
${0} stop
sleep 1
${0} start
;;
status)
statusproc /usr/sbin/collectd
;;
backup)
# Backup all data if ramdisk is used
if mountpoint "${RRDLOG}" &>/dev/null; then
${0} restart
fi
;;
*)
echo "Usage: $0 {start|stop|restart|status|backup}"
exit 1
;;
esac
# End $rc_base/init.d/collectd