#! /bin/sh
|
|
|
|
PATH=/sbin:/usr/sbin:/bin:/usr/bin:/usr/local/sbin:/usr/local/bin
|
|
|
|
NAME=nut
|
|
DESC="Network UPS Tools"
|
|
DEFAULT=/etc/sysconfig/nut
|
|
CONFIG=/etc/nut/nut.conf
|
|
|
|
. /etc/sysconfig/rc
|
|
. $rc_functions
|
|
|
|
# set upsd specific options. use "man upsd" for more info
|
|
UPSD_OPTIONS=""
|
|
|
|
# set upsmon specific options. use "man upsmon" for more info
|
|
UPSMON_OPTIONS=""
|
|
|
|
# Include defaults if available (transition period)
|
|
if [ -f $DEFAULT ] ; then
|
|
. $DEFAULT
|
|
fi
|
|
|
|
# Include NUT nut.conf
|
|
if [ -f $CONFIG ] ; then
|
|
. $CONFIG
|
|
fi
|
|
|
|
# Explicitly require the configuration to be done in /etc/nut/nut.conf
|
|
if [ "x$MODE" = "xnone" ] ; then
|
|
log_failure_msg "$NAME disabled, please adjust the configuration to your needs "
|
|
log_failure_msg "and then set MODE to a suitable value in $CONFIG to enable it."
|
|
# exit success to avoid breaking the install process!
|
|
exit 0
|
|
fi
|
|
|
|
upsd=/usr/sbin/upsd
|
|
upsdrvctl=/usr/bin/upsdrvctl
|
|
upsmon=/usr/sbin/upsmon
|
|
log=">/dev/null 2>/dev/null"
|
|
|
|
start_stop_server () {
|
|
case "$MODE" in
|
|
standalone|netserver)
|
|
case "$1" in
|
|
start)
|
|
! $upsdrvctl start >/dev/null 2>&1 && boot_mesg "(upsdrvctl failed)"
|
|
$upsd $UPSD_OPTIONS >/dev/null 2>&1
|
|
evaluate_retval
|
|
;;
|
|
stop)
|
|
$upsd -c stop >/dev/null 2>&1
|
|
evaluate_retval
|
|
! $upsdrvctl stop >/dev/null 2>&1 && boot_mesg "(upsdrvctl failed)"
|
|
;;
|
|
esac
|
|
;;
|
|
none|netclient|*)
|
|
return 1
|
|
;;
|
|
esac
|
|
}
|
|
|
|
start_stop_client () {
|
|
case "$MODE" in
|
|
standalone|netserver|netclient)
|
|
case "$1" in
|
|
start)
|
|
$upsmon $UPSMON_OPTIONS >/dev/null 2>&1
|
|
evaluate_retval
|
|
;;
|
|
stop)
|
|
$upsmon -c stop >/dev/null 2>&1
|
|
evaluate_retval
|
|
;;
|
|
esac
|
|
;;
|
|
none|*)
|
|
return 1
|
|
;;
|
|
esac
|
|
}
|
|
|
|
status_server () {
|
|
case "$MODE" in
|
|
standalone|netserver)
|
|
statusproc $upsd
|
|
statusproc $upsmon
|
|
;;
|
|
none|netclient|*)
|
|
return 1
|
|
;;
|
|
esac
|
|
}
|
|
|
|
status_client () {
|
|
case "$MODE" in
|
|
standalone|netclient)
|
|
statusproc $upsmon
|
|
;;
|
|
none|*)
|
|
return 1
|
|
;;
|
|
esac
|
|
}
|
|
|
|
case "$1" in
|
|
|
|
start)
|
|
boot_mesg "Starting $DESC ..."
|
|
start_stop_server start
|
|
start_stop_client start
|
|
;;
|
|
|
|
stop)
|
|
boot_mesg "Stopping $DESC ..."
|
|
start_stop_server stop
|
|
start_stop_client stop
|
|
;;
|
|
|
|
reload)
|
|
$upsd -c reload >/dev/null 2>&1
|
|
$upsmon -c reload >/dev/null 2>&1
|
|
;;
|
|
|
|
status)
|
|
status_server
|
|
status_client
|
|
;;
|
|
|
|
restart|force-reload)
|
|
boot_mesg "Restarting $DESC ..."
|
|
start_stop_client stop
|
|
start_stop_server stop
|
|
sleep 5
|
|
start_stop_server start
|
|
start_stop_client start
|
|
;;
|
|
|
|
poweroff)
|
|
flag=`sed -ne 's#^ *POWERDOWNFLAG *\(.*\)$#\1#p' /etc/nut/upsmon.conf`
|
|
wait_delay=`sed -ne 's#^ *POWEROFF_WAIT= *\(.*\)$#\1#p' $CONFIG`
|
|
if [ -f "$flag" ] ; then
|
|
if $upsmon -K >/dev/null 2>&1 ; then
|
|
boot_mesg "Shutting down the UPS ..."
|
|
sleep 1
|
|
if $upsdrvctl shutdown ; then
|
|
sleep 5
|
|
boot_mesg "Waiting for UPS to cut the power"
|
|
else
|
|
boot_mesg "Shutdown failed."
|
|
boot_mesg "Waiting for UPS batteries to run down"
|
|
fi
|
|
if [ "$wait_delay" ] ; then
|
|
boot_mesg " (will reboot after $wait_delay) ..."
|
|
sleep "$wait_delay"
|
|
/etc/init.d/reboot stop
|
|
fi
|
|
else
|
|
boot_mesg "Power down flag is not set (UPS shutdown not needed)"
|
|
fi
|
|
else
|
|
if [ -z "$flag" ] ; then
|
|
boot_mesg "##########################################################"
|
|
boot_mesg "## POWERDOWNFLAG is not defined in /etc/nut/upsmon.conf ##"
|
|
boot_mesg "## ##"
|
|
boot_mesg "## Please read the Manual page upsmon.conf(5) ##"
|
|
boot_mesg "##########################################################"
|
|
fi
|
|
fi
|
|
;;
|
|
|
|
*)
|
|
N=/etc/init.d/$NAME
|
|
echo "Usage: $N {start|stop|status|reload|restart|force-reload|poweroff}" >&2
|
|
exit 1
|
|
;;
|
|