mirror of
https://github.com/vincentmli/bpfire.git
synced 2026-04-27 19:23:24 +02:00
Updated kernel (2.6.32.8).
This commit is contained in:
73
lfs/linux
73
lfs/linux
@@ -24,8 +24,8 @@
|
||||
|
||||
include Config
|
||||
|
||||
PATCHLEVEL = .42
|
||||
VER = 2.6.27.42
|
||||
PATCHLEVEL = .8
|
||||
VER = 2.6.32.8
|
||||
|
||||
THISAPP = linux-$(VER)
|
||||
DL_FILE = $(THISAPP).tar.bz2
|
||||
@@ -35,42 +35,42 @@ CFLAGS =
|
||||
CXXFLAGS =
|
||||
|
||||
PROG = linux-xen
|
||||
PAK_VER = 7
|
||||
PAK_VER = 8
|
||||
DEPS = ""
|
||||
|
||||
# Normal build or XEN build.
|
||||
#
|
||||
|
||||
ifeq "$(XEN)" "1"
|
||||
VERSUFIX=ipfire-xen
|
||||
else
|
||||
VERSUFIX=ipfire
|
||||
endif
|
||||
|
||||
TARGET = $(DIR_INFO)/linux-$(VER)-$(VERSUFIX)
|
||||
|
||||
###############################################################################
|
||||
# Top-level Rules
|
||||
###############################################################################
|
||||
objects =$(DL_FILE) \
|
||||
squashfs3.4.tar.gz \
|
||||
netfilter-layer7-v2.21.tar.gz \
|
||||
netfilter-layer7-v2.22.tar.gz \
|
||||
patch-2.6.16-nath323-1.3.bz2 \
|
||||
reiser4-for-2.6.27.19.patch.bz2 \
|
||||
linux-$(VER)-suse_xen_patches-1.tar.bz2
|
||||
reiser4-for-2.6.32.patch.bz2 \
|
||||
# linux-$(VER)-suse_xen_patches-1.tar.bz2
|
||||
|
||||
$(DL_FILE) = $(URL_IPFIRE)/$(DL_FILE)
|
||||
netfilter-layer7-v2.21.tar.gz = $(URL_IPFIRE)/netfilter-layer7-v2.21.tar.gz
|
||||
netfilter-layer7-v2.22.tar.gz = $(URL_IPFIRE)/netfilter-layer7-v2.21.tar.gz
|
||||
patch-2.6.16-nath323-1.3.bz2 = $(URL_IPFIRE)/patch-2.6.16-nath323-1.3.bz2
|
||||
squashfs3.4.tar.gz = $(URL_IPFIRE)/squashfs3.4.tar.gz
|
||||
reiser4-for-2.6.27.19.patch.bz2 = $(URL_IPFIRE)/reiser4-for-2.6.27.19.patch.bz2
|
||||
linux-$(VER)-suse_xen_patches-1.tar.bz2 = $(URL_IPFIRE)/linux-$(VER)-suse_xen_patches-1.tar.bz2
|
||||
reiser4-for-2.6.32.patch.bz2 = $(URL_IPFIRE)/reiser4-for-2.6.32.patch.bz2
|
||||
#linux-$(VER)-suse_xen_patches-1.tar.bz2 = $(URL_IPFIRE)/linux-$(VER)-suse_xen_patches-1.tar.bz2
|
||||
|
||||
|
||||
$(DL_FILE)_MD5 = a33e6b22d70dd010525fc43cdda36792
|
||||
netfilter-layer7-v2.21.tar.gz_MD5 = 838422e7d9a06b42e682e9064e5210b5
|
||||
$(DL_FILE)_MD5 = 82023ede52f067fcc55c5e70b02e48ae
|
||||
|
||||
netfilter-layer7-v2.22.tar.gz_MD5 = 98dff8a3d5a31885b73341633f69501f
|
||||
patch-2.6.16-nath323-1.3.bz2_MD5 = f926409ff703a307baf54b57ab75d138
|
||||
squashfs3.4.tar.gz_MD5 = 2a4d2995ad5aa6840c95a95ffa6b1da6
|
||||
reiser4-for-2.6.27.19.patch.bz2_MD5 = 22988387f64f299489b90b484b2642cc
|
||||
linux-$(VER)-suse_xen_patches-1.tar.bz2_MD5 = ddbde50f3bc303d947531402017a3055
|
||||
reiser4-for-2.6.32.patch.bz2_MD5 = 3246397973d9271eb8e6d7c97c5d2d91
|
||||
#linux-$(VER)-suse_xen_patches-1.tar.bz2_MD5 = ddbde50f3bc303d947531402017a3055
|
||||
|
||||
install : $(TARGET)
|
||||
|
||||
@@ -102,6 +102,7 @@ $(subst %,%_MD5,$(objects)) :
|
||||
$(TARGET) : $(patsubst %,$(DIR_DL)/%,$(objects))
|
||||
@$(PREBUILD)
|
||||
@rm -rf $(DIR_APP) $(DIR_SRC)/linux $(DIR_SRC)/linux-*-suse_xen_patches $(DIR_SRC)/xen-* && cd $(DIR_SRC) && tar jxf $(DIR_DL)/$(DL_FILE)
|
||||
|
||||
ln -s linux-$(VER) /usr/src/linux
|
||||
|
||||
ifeq "$(XEN)" "1"
|
||||
@@ -120,43 +121,29 @@ ifeq "$(XEN)" "1"
|
||||
cd $(DIR_APP) && patch -Np1 < $(DIR_SRC)/src/patches/linux-2.6.27.21-imq-test3-xen.patch
|
||||
else
|
||||
# Linux Intermediate Queueing Device
|
||||
cd $(DIR_APP) && patch -Np1 < $(DIR_SRC)/src/patches/linux-2.6.27.21-imq-test3.patch
|
||||
cd $(DIR_APP) && patch -Np1 < $(DIR_SRC)/src/patches/linux-2.6.32-imq-test2.patch
|
||||
endif
|
||||
|
||||
# Add Vodafone K3565-Z USB ID's to option driver
|
||||
cd $(DIR_APP) && patch -Np1 < $(DIR_SRC)/src/patches/linux-2.6.27.25-option_add_vf-k3565-z_usbids.patch
|
||||
|
||||
# Add Alix to Led Driver
|
||||
cd $(DIR_APP) && patch -Np1 < $(DIR_SRC)/src/patches/linux-2.6.24-leds-alix.patch
|
||||
|
||||
# Patch to fix Intel e100 wake on lan
|
||||
cd $(DIR_APP) && patch -Np1 < $(DIR_SRC)/src/patches/linux-2.6.27.39_e100-wakeonlan-fix.patch
|
||||
# # Add Vodafone K3565-Z USB ID's to option driver
|
||||
# cd $(DIR_APP) && patch -Np1 < $(DIR_SRC)/src/patches/linux-2.6.27.25-option_add_vf-k3565-z_usbids.patch
|
||||
|
||||
# Not report deprecated syscall 1.23 (for kudzu)
|
||||
cd $(DIR_APP) && patch -Np1 < $(DIR_SRC)/src/patches/linux-2.6.25.18-not_report_sysctl_1.23.patch
|
||||
|
||||
ifeq "$(XEN)" ""
|
||||
# Reiser4
|
||||
-cd $(DIR_APP) && bzip2 -d -c $(DIR_DL)/reiser4-for-2.6.27.19.patch.bz2 | patch -Np1
|
||||
|
||||
# SquashFS (already in Suse Patchset)
|
||||
cd $(DIR_SRC) && rm -rf squashfs*
|
||||
cd $(DIR_SRC) && tar xfz $(DIR_DL)/squashfs3.4.tar.gz
|
||||
cd $(DIR_APP) && patch -Np1 < $(DIR_SRC)/squashfs3.4/kernel-patches/linux-2.6.27-rc4/squashfs3.4-patch
|
||||
cd $(DIR_APP) && bzcat $(DIR_DL)/reiser4-for-2.6.32.patch.bz2 | patch -Np1
|
||||
endif
|
||||
|
||||
# ipp2p 0.8.2-pomng
|
||||
cd $(DIR_APP) && patch -Np1 < $(DIR_SRC)/src/patches/linux-2.6.27.19-ipp2p-0.8.2-pomng.patch
|
||||
cd $(DIR_APP) && patch -Np1 < $(DIR_SRC)/src/patches/linux-2.6.32.8-ipp2p-0.8.2-pomng.patch
|
||||
|
||||
# Intel Atom Coretemp Patch
|
||||
cd $(DIR_APP) && patch -Np1 < $(DIR_SRC)/src/patches/linux-2.6.27-atom-coretemp.patch
|
||||
|
||||
# Layer7-patch
|
||||
cd $(DIR_SRC) && rm -rf $(DIR_SRC)/netfilter-layer7-v2.21
|
||||
cd $(DIR_SRC) && tar xzf $(DIR_DL)/netfilter-layer7-v2.21.tar.gz
|
||||
cd $(DIR_APP) && patch -Np1 < $(DIR_SRC)/netfilter-layer7-v2.21/kernel-2.6.25-2.6.28-layer7-2.21.patch
|
||||
cd $(DIR_SRC) && rm -rf $(DIR_SRC)/netfilter-layer7-v2.22
|
||||
cd $(DIR_SRC) && tar xzf $(DIR_DL)/netfilter-layer7-v2.22.tar.gz
|
||||
cd $(DIR_APP) && patch -Np1 < $(DIR_SRC)/netfilter-layer7-v2.22/kernel-2.6.25-2.6.28-layer7-2.22.patch
|
||||
|
||||
# Cleanup kernel source
|
||||
cd $(DIR_APP) && make mrproper
|
||||
|
||||
cp $(DIR_SRC)/config/kernel/kernel.config.$(MACHINE)-$(VERSUFIX) $(DIR_APP)/.config
|
||||
cd $(DIR_APP) && make CC="$(KGCC)" oldconfig
|
||||
@@ -186,10 +173,12 @@ endif
|
||||
# Rename ide-cd module to match with old kernel
|
||||
mv /lib/modules/$(VER)-$(VERSUFIX)/kernel/drivers/ide/ide-cd_mod.ko \
|
||||
/lib/modules/$(VER)-$(VERSUFIX)/kernel/drivers/ide/ide-cd.ko
|
||||
mv /lib/modules/$(VER)-$(VERSUFIX)/kernel/drivers/ide/ide-gd_mod.ko \
|
||||
/lib/modules/$(VER)-$(VERSUFIX)/kernel/drivers/ide/ide-disk.ko
|
||||
|
||||
# Remove mISDN modules
|
||||
rm -rvf /lib/modules/$(VER)-$(VERSUFIX)/kernel/drivers/isdn/mISDN
|
||||
rm -rvf /lib/modules/$(VER)-$(VERSUFIX)/kernel/drivers/isdn/hardware/mISDN
|
||||
# # Remove mISDN modules
|
||||
# rm -rvf /lib/modules/$(VER)-$(VERSUFIX)/kernel/drivers/isdn/mISDN
|
||||
# rm -rvf /lib/modules/$(VER)-$(VERSUFIX)/kernel/drivers/isdn/hardware/mISDN
|
||||
|
||||
@rm -rf $(DIR_SRC)/patch-o-matic* $(DIR_SRC)/iptables* $(DIR_SRC)/squashfs* $(DIR_SRC)/netfilter-layer7-*
|
||||
@$(POSTBUILD)
|
||||
|
||||
Reference in New Issue
Block a user